LEHU乐虎国际

LEHU乐虎国际

OLYMPUS IX83

The fully motorized IX83 is the most advanced member of the IX3 series of inverted imaging systems and offers a new level of application flexibility. Choose from the one-deck system with a low, ergonomic stage or the two-deck system with additional expansion capabilities. Both provide the ability to perform a multitude of imaging applications, from long-term time-lapse imaging and other demanding techniques to routine testing and documentation.

  • Price:
  • Brand: OLYMPUS
  • Model: IX83

Expandable to Meet Growing Research Needs

The fully-motorized IX83 is designed to satisfy a variety of research needs. With additional modules providing expanded functionality, both microscope options enable a multitude of imaging techniques, ranging from casual documentation to long-term time-lapse imaging and other demanding techniques.
The unique open frame of the IX83 provides ready access to the light path, thus making it easy to add or change modules. A variety of deck modules can be easily exchanged to add or remove functions as needed. With a simple slide-in design, the IX3-ZDC2 Z drift compensator module can be easily added to any IX83 system to maintain continuous focus throughout an extended time-lapse experiment.

IX83: Two-deck System

Enables high-speed, fully automated device selction during live cell research and advanced image acquisition. The two-deck configuration provides excellent expandability.

1503106760309014

IX83: One-deck System

An intelligent, motorized microscope featuring a large field number (FN22, left side port) and IX3-ZDC2 compatibility, thus creating a new standard for live cell imaging.

1503106781211569

Reliable, Clear and Bright High-Resolution Images

Olympus UIS2 infinity-corrected optics ensure high optical transmittance with a broad range of objectives. UIS2 optics feature wide chromatic correction and enable high resolution, high S/N primary images regardless of the observation method. The wide field of view and Fly-Eye lens system provide uniform fluorescence images and enable the use of sCMOS cameras with large sensors.

1503106800867025

Apochromatic Objectives Enable High-Resolution Phase Contrast and Fluorescence Observation

Phase contrast apochromatic objectives (UPLSAPO100XOPH, PLAPON60XOPH) enable high-precision imaging free from image shift, even during simultaneous phase contrast and fluorescence observation. This eliminates the need to change objectives when switching observation methods.

1503106829683233  1503106829689800  1503106829408082

Silicone Objectives* Enable High-Resolution Observation Deep in o Live Cells

Olympus offers three high-NA silicone immersion objectives:UPLSAPO30XS, UPLSAPO40XS, and UPLSAPO60XS. The refractive index of silicone oil (Refractive index: ne≈1.40) is close to that of living tissue (Refractive index: ne≈1.38), enabling high-resolution observation deep inside living tissue with minimal spherical aberration caused by refractive index mismatch. Silicone oil does not dry out or harden, so there is never a need to readminister the oil, making it ideal for extended time-lapse observations.

*Use dedicated silicone oil.

1503106903529851  1503106903506818

Special Objective Available for iPS/ES and Floating Cell Observation

This high-NA phase contrast objective (UCPLFLN20XPH) is especially suited for observation using plastic dishes. It enables high-resolution observation of the cell proliferation process and delivers improved contrast across a wide area.

1503106981268160  1503106981660786  1503106981136412

Bright, Uniform Fluorescence Illumination

The fluorescence illuminator (IX3-RFALFE) incorporates a Fly-Eye lens system to provide even light distribution. This provides bright and even illumination to the entire field, including the periphery of the visual field.

1503107071872125  1503107071330013

High S/N Fluorescence Mirror Units for Efficient Signal Detection

All fluorescence mirror units feature filters treated with a specially-developed coating that minimizes noise by absorbing more than 99% of stray light. The outstanding performance and high transmittance of the mirror units ensure efficient fluorescence signal detection.

1503107366116951  1503107366366312  1503107123228459

Smart Control

Switch Observation Methods with a Single Touch

Olympus includes a touch panel controller with the IX83 that allows the user to easily configure all automated functions on the microscope. This includes advanced functions such as magnification-specific lamp intensity adjustment. The touch panel controller, used in combination with cellSens software, enables advanced customization.

1503107348901819

ZDC One-Shot Function Quickly Detects Focus, Even during High-Magnification Observation

IX3-ZDC2 focus detection and tracking can be performed through the innovative touch panel controller, independent of software. There is also a focus search function supported by a cell-safe, near-infrared laser, allowing users to instantly focus on samples, even at high magnification.

1503107412131272

Intuitive Microscope and XY Stage Controllers

The U-MCZ focus module and XY stage controller provide the familiarity of conventional handle operation for intuitive microscope control, even in a darkroom environment. 

1503107425333578

Stored Microscope Configurations (Olympus cellSens)

The system saves microscope configurations alongside image data by incorporating a readout of motorized and coded unit position. With this advanced system, a wide range of settings can be recalled to recreate the desired imaging conditions, thereby creating a highly reproducible and easy-to-use, high-end imaging system.

1503107451685864

Reliable Tracking at High Magnification

The IX3-SVR manual stage features a reliable positioning system which enables the easy tracking of cells, even at high magnifications. The travel limits can be manipulated by the user to immobilize the stage and prevent inadvertent movement during critical operations. It is also possible to remove the 35mm dishes from the stage, place them in an incubator and return them to the exact previously identified.

1503107495262091

Easily Achieve Koehler Illumination

The condenser can be moved and easily reset to Koehler Illumination using the conveniently-located condenser lock and control knobs.

1503107524263001

Catch Tray Minimizes Optical System Contamination

A catch tray under the nosepiece minimizes the possibility of contaminating and damaging the microscope with spilled liquids. This feature also simplifies maintenance.

1503107568418559

Ideally Suited for Live Cell Imaging

Easily capture dynamic cellular processes with the IX83, an imaging system designed for remarkable time-lapse imaging. With new frame architecture and focus drive design, the IX3 system offers enhanced rigidity that reduces the impact of vibration and temperature. It maintains desired positions along the X, Y, and Z axes to facilitate reliable time-lapse and multipoint imaging.

1503107584854674
When combined with the Olympus IX3-SSU ultrasonic stage and Z drift compensator (IX3-ZDC2) , the IX83 is perfectly suited for capturing high-precision, multipoint time-lapse images that are never out of focus or misaligned. Box-type and stage-top incubators are also available to maintain the viability of live cells during time-lapse experimentation.

1503107652780537  1503107652208883

Z Drift Compensation System (IX3-ZDC2)

The new, fully motorized Olympus Z drift compensation module combats focal drift to keep the sample in sharp focus during long-term, time-lapse experiments.  The improved IX3-ZDC2 is faster, more flexible and supports a larger range of objectives and sample vessels.
One-shot autofocus (AF) mode allows several focus positions to be set as desired for thicker samples, enabling efficient Z-stack acquisition in multi-position experiments. The enhanced continuous AF mode, now also supporting dry objectives, keeps the desired plane of observation precisely in focus, even during the addition of reagents or changes in room temperature.

1503107744993070  1503107744796701

High-precision Ultrasonic Stage for IX3 (IX3-SSU)

With low thermal drift and high accuracy, the ultrasonic stage delivers excellent reliability for multi-image acquisition. Sample holders firmly secure slides or dishes to ensure accurate repeatability during high-magnification, multi-point observations.

1503107845473665  1503107846846408

Efficient Multi-Image Acquisition with cellSens Software

The IX3 ultrasonic stage can be used with cellSens software to conduct multi-area time-lapse imaging with greater efficiency. Image cell dynamics at multiple points within each well and join adjacent fields to create wide area, time-lapse images and obtain a greater amount of data from the same experiment. The excellent accuracy and repeatability of the ultrasonic stage makes it easy to obtain seamless tiled images with cellSens software.

1503107912146392  1503107912942732

Motorized DIC Slider for IX83

The motorized IX3-DICTA allows users to engage and adjust DIC without disturbing the sample.

1503107994521449

Interchangeable Modules Provide Flexible Imaging Options

A wide range of units are available for the Olympus IX3 microscope system, bringing enhanced usability to everything from casual observation to high-end imaging. Simple cassette-like insrtion in o the deck makes it easy to mount fluorescence mirror turrets, right side ports, mag changers, epi-illuminators and other units. 

1503108017368803

The large open frame allows a motorized emission filter wheel to be fitted within the infinity space of the microscope. This eliminates image shift between channels and allows the eyepieces to see what the camera detects.

1503108034170321

Motorized Fluorescence Mirror Turret (IX3-RFACA)

A non-click turret that can be fitted with up to 8 mirror units and that delivers smooth, rapid cube rotation. The turret can accommodate both 25mm and 32mm diameter filter units, which can easily be insrted and removed without the need of tools.  

1503108063994542

Motorized/Manual Right Side Port with C-mount (IX3-RSPCA/IX3-RSPC)

The C-mount-equipped right side ports can be fitted with up to two mirror units, enabling advanced applications such as split imaging.

1503108109444548

Coded Intermediate Magnification Changer (IX3-CAS)

Magnification can be easily changed between 1X, 1.6X and 2X by adjusting the lever. Since the system is coded, information on intermediate magnifications is saved with image data.

1503108122729217

Motorized Fast Filter Wheels and Shutters

With Olympus filter wheels, the user can easily switch between filters in milliseconds. Olympus shutters operate even faster. The IX83 is capable of controlling up to six filter wheels and four shutters, thus enabling complex, multi-modal imaging.

1503108197389002

Application-Specific Fluorescence Illuminators

There is an illuminator best-suited for each application. The L-shaped fluorescence illuminator with the Fly-Eye lens system (IX3-RFALFE) provides bright, even  illumination without adjustment. The standard L-shaped fluorescence illuminator (IX3-RFAL) is cost-effective and is equipped with both field and aperture iris diaphragms. The straight fluorescence illuminator (IX3-RFA) is ideal for applications demanding intense excitation light. A wide range of light sources is also available, including counter top and frame-mounted units (mercury and xenon). 

1503108207499672

Long Life 130W Mercury Lamp (U-HGLGPS)

The U-HGLGPS fluorescence light source delivers bright, even illumination and features a long life, 2,000-hour mercury burner (average lifetime). The unit is maintenance-free and does not require centering adjustment. A liquid light guide prevents heat transfer to samples, thus allowing extended observations to be carried out without concern.

1503108217818035

Measuring Excitation Light Intensity for High Reproducibility in Imaging Adapter for Excitation Irradiance Meter/IX3-EXMAD*

Olympus now offers an adapter for a power meter that can directly measure the excitation light intensity per unit surface area of the sample, as well as offering irradiance display software. Displays the measurement results on a monitor and records the data, eliminating The need for laborious calculations. This makes it possible to check the excitation light intensity before starting an experiment, enhancing the reliability of experiments. Data can also be easily shared.
*This equipment was based on the technical development at RIKEN BSI-Olympus Collaboration Center.

1503108229754869

标签: OLYMPUS IX83
在线地图
QQ客服